Usage Example - Operation: 'AP SR'

Alignment - reference free, Shift & Rotation

Procedure used: apsr.spi


.OPERATION: AP SR ;   Alignment determination
.TEMPLATE FOR IMAGE SERIES TO BE ALIGNED: sav_face_rtsh_stk@***;   Image name template (input)
.FILE NUMBERS OR SELECTION DOC. FILE NAME: 1-80 ;   List of Exp images
.EXPECTED SIZE OF OBJECT: 52 ;   Object size
.FIRST & LAST RING: 5, 149 ;   First & last ring
.IMAGE TO BE USED TO CENTER THE AVERAGE : * ;   Use blob for initial alignment image
.TEMPLATE FOR AVERAGE FILES: apsr_*** ;   Aligned image template (output)
.TEMPLATE FOR ALIGNMENT DOC FILES: apsr_doc_*** ;   Alignment doc file template (output)



EXP INPUT IMAGES
(80 Images)
sav_face_rtsh_stk_mon



OUTPUT ALIGNED IMAGES
apsr_mon



OUTPUT ALIGNMENT DOC FILE
(one of six)
apsr_doc_01



<