Single Particle Reconstruction with Reference Projections using SPIRE


This page describes how to do a 3D single particle reconstruction project using SPIRE.
Each step of a project is accomplished by running a series of SPIDER procedure files, described on the Single Particle Reconstruction web page.
SPIRE provides a graphical interface for running procedure files, and keeps track of all data files that are part of a project.

Starting a project in SPIRE
Project parameters
Input files needed for a reconstruction project
Running SPIDER procedure files
File numbers
Viewing procedure file outputs
The SPIRE manual



Starting a project in SPIRE

At the start of a reconstruction project, a project directory has to be set up with the proper subdirectories and procedure files. SPIRE keeps all information about a project in a project file.


When you first start a project, start SPIRE by typing
     spire
Once you have created a project file, usually called something like proj145, the next time you can open SPIRE by including the file's name on the command line, e.g.:
     spire proj145

Starting a new project

Under the Project menu, select New. This opens the New Project window:

Project parameters: the parameter file

Project-wide parameters are kept in a SPIDER document file, usually called params.ext. These are accessed by numerous procedure files. See the description of single particle reconstruction parameters.

When you start a new project, SPIRE opens up a Project Parameters window. (If it doesn't, then under the Parameters menu, select New.) Be sure to fill in values for:

zip flag: whether or not the micrographs are zipped (i.e., have the extension .gz).
file format: (of micrographs) May be SPIDER or output from a scanner.
pixel size: Angstroms/pixel after scanning. Pixel size also sets the values for
max.spatial frequency, window size, and particle size
electron energy: (kV) Also sets lambda
spherical aberration: Set appropriate value for Microscope
particle window size: (in pixels) diameter of the small particle images
particle diameter: (in pixels, approximate) default values are for Ribosome!!

You can fill in the other fields, or just use the default values.
NB: after you enter a pixel size, values will automatically be calculated for maximum spatial frequency, window size, and particle size. Make sure these are the values you wish to use!

Click OK, and SPIRE will save these values to the parameter doc file. Alternatively, you can read in values from a parameter file from a previous project.

Input files needed for a reconstruction project

  1. The digitized micrographs should be in the Micrographs directory.
    Or, because they require so much disk space, it may be desirable to keep the micrographs in another location, and make Micrographs a symbolic link. In that case, cd to your project directory, remove Micrographs, and make a symbolic link:
         
    rmdir Micrographs
          ln -s /actual/location/of/the/micrographs Micrographs
    Your parameter file must reflect whether your micrographs are
         a) In SPIDER or some other format,
         b) Whether or not they are zipped (i.e., have the extension .gz).
  2. A reference volume is required for reconstruction using reference projections. If the dimensions of your reference volume do not match the window size (key 17 in the parameter file), then you must resize the volume with resizevol.spi. This procedure file should be run in the top-level project directory, creating a new, resized reference volume called reference_volume.ext.
  3. An image of background noise is needed by the particle picking procedure files lfc_pick.spi and pick.spi. Although a file can be generated by the procedure file noise.spi, ask your advisor if there is already a noise image being used to normalize the particle image set.

Running SPIDER procedure files

Each section of a reconstruction project is presented in a Dialog window. Dialogs list a set of Run buttons, which execute SPIDER with the specified procedure file. Each procedure file also has an Edit button. Before running a procedure file, you should always open it in Edit mode, and check that its parameters, inputs and outputs are correct.

- Execute the SPIDER procedure file by clicking its Run buttons.
- A small Process window will open to indicate that the procedure file is active. Any printed output will be sent to the SPIRE main window.
- If the procedure file completes succesfully, **** SPIDER NORMAL STOP **** will display in the main window, and information about that particular run will be saved to the project file.
- If SPIDER stops on an error condition, the last few lines of the results file will be displayed to indicate the problem.

File numbers

Some procedure files use a special parameter called [FILENUMS], which points to a document file that selects which input files are to be processed. The contents of the file numbers document file (usually called filenums.ext) can be controlled by the File numbers entry box in the lower left corner of the main SPIRE window. With the cursor in the File numbers entry box, hitting the Enter key writes the displayed values into the filenums file.

Sometimes it is useful to try out a procedure file with a single file. Once you've established that it runs correctly, set the file numbers to the rest of the input data files. If you run the same procedure file with different file numbers each time, those are considered distinct procedure runs.

Viewing procedure file outputs

SPIDER procedure files generate output data files, either text (document files), or binary (images, volumes, image stacks, etc). When a procedure file completes successfully, it is saved to the project file. You can see which procedure files you have run, as well as examine their output files, in the SPIRE Project Viewer. Under the Commands menu, select View project. This brings up the Project Viewer with completed procedure runs in the upper window. Clicking on a procedure run in the upper window displays the output files for that procedure in the lower window. Clicking on an output file displays it. Image files are displayed in Jweb; documents are displayed in a text editor.


Using SPIRE

If you are unfamiliar with SPIRE you should have the SPIRE documentation handy. This includes instructions on:

Ready to start using SPIDER? Then go back to the single particle reconstruction page, skip the section "Running SPIDER procedure files", and proceed directly to Contrast Transfer Function estimation.